Rental- 800 LPAC System- Naval Base Point Loma, San Diego, CA (PLOMA) Amendment 0002


Subject: Rental- 800 LPAC System- Naval Base Point Loma, San Diego, CA (PLOMA) Amendment 0002
Solicitation Number: N3904027Q0010
Notice Type: SOLICIT
NAICS: 532490
Set-Aside: Total Small Business
Notice Published: 10-21-26
Response Due: 10-22-26

Agency: Department of the Navy
Office: PORTSMOUTH NAVAL SHIPYARD GF
Contact: Bob Watters This email address is being protected from spambots. You need JavaScript enabled to view it. Ph: (207) 438-2205
Office Address: PORTSMOUTH, NH 03801-5000
Place of Performance: San Diego, CA 92152

Related Notices:
        10-19-26 SOLICIT

        10-16-26 SOLICIT


Click for official SAM (FBO) notice, additional information, and accompanying attachments

Amendement 0002 is isuued to extend this solication to provide responses to vendor questions received on October 20, 2026. Please see the responses below, provided in bold: Question: would the government accept two Aggreko 400 CFM electric, oil-free compressors operating as one coordinated 800 CFM system, provided all applicable performance, safety, and electrical requirements are satisfied. Answer: No Question: please clarify the requirement for a maximum discharge-air temperature of 100?F while operating in ambient temperatures up to 110?F Answer: Discharge of the compressor shall have a maximum temperature of 100 deg F while it operates outside in the sun in an environment that may reach 110 deg F Question: could you please confirm whether the contractor is also responsible for routing air hoses throughout the ship and connecting them to individual shipboard air inlets, or whether those connections will be handled by government personnel? Answer: The shipboard routing and connections will be handled by government personnel Amendement 0001 is isuued to provide responses to vendor questions received om October 19, 2026. Please see the responses below, provided in bold: Question: Will the compressor operate continuously, 24 hours per day, seven days per week? If not, what are the estimated operating hours per week? Answer:The project will use this compressor whenever is needed for as long as needed. Question: Is the required 800 SCFM measured at the compressor discharge or at the point of use after accounting for dryer purge consumption? Answer: The discharge of the compressor Question: Please confirm the government will provide suitable electrical sources for both the compressor and dryer. Who is responsible for making the final electrical connections? The government will provide suitable electrical sources, however, the contractor will be responsible for making the final connection. Q: Can the government provide an estimated routing distance or layout for the remote emergency-stop cable so we can price the installation accurately? Answer: The contractor shall be prepared to provide and route up to 1500 ft of e stop cabling. Q: CLIN 0003 covers training during the five-week base period. Should any training required during the optional extension be included in CLIN 1001? Answer: No training required for the optional extension CLIN 1001 Rental of one (1) Electric 800 CFM Low Pressure Air Compressor (oil free) Naval Base Point Loma, San Diego, CA PLOMA Portsmouth Naval Shipyard (PNSV) is seeking to rent one (1) Electric 800 CFM Low Pressure Air Compressor (oil free). The Statement of Work (SOW) outlines the specifications that meet the essential requirements for the procurement of rental equipment necessary to to establish a tool air system. The application for this equipment is located at Naval Base Point Loma, San Diego, CA PLOMA. Solicitation Number: N3904027Q0010 Response Deadline: October 21, 2026, at 12:30 PM (EST) POC: Bob Watters, This email address is being protected from spambots. You need JavaScript enabled to view it. Required Delivery Date/Period of Performance: Base period: 11/02/2026 - 12/06/2026 (5 weeks) Option Period 1: 12/07/2026 - 12/20/2026 (2 - weeks) Place of Performance: Naval Base Point Loma, San Diego, CA PLOMA METHOD OF PROPOSAL SUBMISSION Offers shall be emailed. All responsible sources may submit a quote which shall be considered by the agency. System for Award Management (SAM): Vendors must be registered in the SAM database to be considered for award. Registration is free and can be completed on-line at http://www.sam.gov/. All quotes shall include the embedded Request for Quote (RFQ). All quotes must have the highlighted sections completed. Please make sure to include all technical data sheets and information relating to the rental equipment.