Fire Suppression Sprinklers at Coatesville VAMC


Subject: Fire Suppression Sprinklers at Coatesville VAMC
Solicitation Number: 36C24426Q0415
Notice Type: SOLICIT
NAICS: 811310
Set-Aside: Service-Disabled Veteran-Owned Small Business
Notice Published: 07-03-26
Response Due: 07-16-26

Agency: Department of Veterans Affairs
Office: VETERANS AFFAIRS, DEPARTMENT OF
Contact: Chris Clements This email address is being protected from spambots. You need JavaScript enabled to view it. Ph: (205) 349-9891
Office Address: PITTSBURGH, PA 15215
Place of Performance: Coatesville, PA 19320

Related Notices:
        07-01-26 SOLICIT

        07-03-26 SOLICIT

        06-30-26 SOLICIT

        07-01-26 SOLICIT


Click for official SAM (FBO) notice, additional information, and accompanying attachments

Amendment 0003 -Delected Base and Option Years for "Program Management" - Added: RFI Questions and Answers -Added: Sprinkler Inspection Reports Statement of Work Five-Year Obstruction Inspection of Sprinkler System Coatesville VA Medical Center 1. Scope The contractor shall provide all labor, materials, equipment, and supervision required to perform the five-year obstruction inspection, testing, and maintenance of the facility?s sprinkler systems in accordance with NFPA (National Fire Protection Association?s) 25 and applicable codes. Work includes internal pipe assessments, valve inspections, FDC hydrostatic testing, hydrant flow testing, and replacement of sprinkler gauges. 2. Applicable Standards All work shall comply with NFPA 25 (current edition) and VA policies and directives. 3. Requirements The contractor shall perform all NFPA 25?required internal inspections, obstruction investigations, fire department connection (FDC) hydrostatic tests, hydrant flow tests, and sprinkler gauge replacements. The contractor shall coordinate all required system shutdowns with the designated VA Point of Contact (POC), adhere strictly to all VA safety protocols, and ensure that all work is performed by properly qualified technicians. All work shall be completed within 30 calendar days of award and shall be conducted Monday through Friday during administrative hours (8:00 a.m. to 4:30 p.m.). No work shall be performed on weekends or Federal holidays. All contractor personnel shall wear visible company identification badges displaying both the company name and the employee?s name. 3.1. Building 1 Annual Inspection The contractor shall perform an annual fire pump inspection in the attic of Building 1 to ensure the stability and integrity of primary VAMC campus location. Flow testing at 100% rated capacity. Measurements of the suction pressure, discharge pressure and flow rate. Manufacturer?s pump curve compared to the current pump performance curve. Documentation of all readings, to include voltage and amperage. Compare to specifications and any deviations requiring corrective action. All equipment evaluations, diagnosis of equipment deficiencies and malfunctions, inspection and acceptance, as well as documentation of all tasks and services provided shall be furnished by the Contractor to the Coatesville VAMC PoC. 3.2. Sprinkler System Maintenance & Internal Inspection A 5-year internal inspection cycle of sprinkler systems will be performed at the Coatesville VAMC Campus. The sprinkler systems gauges will be replaced at the following Buildings: 1, 2, 3, 4, 6, 7, 8, 9, 38, 39, 57, 59, 69, 138 and 139. Building Maintenance will be spread over a 5 year period in which the contractor will have 30 calendar days to complete these services (maintenance, inspection and repairs) of each tranche of buildings. The schedules is as followed: Base Year- Services for Buildings 1, 2, 3 Option Year 1- Services for Buildings 4, 6, 7 Option Year 2- Services for Buildings 8, 9, 38 Option Year 3- Services for Buildings 39, 57, 59 Option Year 4- Services for Buildings 69, 138, 139 Building maintenance will be grouped together with their respective contract years and will billed as one ?job?. Each job shall include the following requirements: service, testing and inspection, maintenance, replacement of all necessary materials, and supplies. The contractor shall provide full maintenance services, including all adjustments, calibration, and tuning. As part of this service, the Contractor shall include diagnosis and evaluation of all equipment, any deficiencies, malfunctions, inspection and acceptance; as well as documentation of all tasks and services provided. 3.3. Miscellaneous Maintenance Repairs Each repair shall include all service, testing and inspection. The Contractor shall provide all parts, materials, supplies, labor, supervision, tools, shipping, travel, and equipment necessary to resolve the deficiency or malfunction. 4. Deliverables Contractor shall submit inspection reports to the VA POC within five business days after work completion. Reports must document inspection findings, deficiencies, photographic evidence where required, and recommended corrective actions. 5. Government Responsibilities The VA POC will provide access to equipment, coordinate fire watch procedures if needed, and review contractor-submitted documentation. 6. References The VA Fire Protection Design Manual (Attachment A) and the Fire Safety Guidebook (Attachment B) are the guidelines supporting this requirement.